For now, the link works for a wide variety of connections/joints. However, please take into account yet unsupported functionality.

Limitation: Non-linear combinations can't be imported to the IDEA StatiCa Checkbot application.


Limitation: Rotation of members using "α" can not be imported from SCIA Engineer to Checkbot

Workaround: Rotate the member using "LCS Rotation" instead, the rotation of members will be imported correctly.

inline image in article


Limitation: Haunches modelled in SCIA Engineer are not imported to Checkbot.

Workaround: The haunches have to be modelled separately in IDEA StatiCa Connection using Operations.

inline image in article

Limitation: Eccentricity modelled using the "member system-line at" is not imported.

Workaround: The eccentricity must be defined via an ez or ey value. The member system line must be set to "Centre".

inline image in article


With SCIA Engineer version 21.1, IDEA StatiCa introduced another option of how to use the BIM link between SCIA Engineer and the Checkbot application.

inline image in article

Limitation: This feature isn't embedded in the Legacy version of SCIA 21.1.

Workaround: Use default UX of SCIA 21.1.


Limitation:  SCIA is unable to create a SAF file used for Bimlink communication. The issue represents itself with the following error in Checkbot and the following message when exporting the SAF model directly from SCIA.

inline image in article

Workaround: To fix it, change the selection of the transfer method from Tributary Area to  Accurate (FEM).

inline image in article

Limitation: Standard combinations can not be imported to the IDEA StatiCa Checkbot Application.

Workaround: Explode the combinations in SCIA Engineer to either envelopes or linear combinations before the export.

inline image in article


Limitation: Members with LCS type defined other than "Standard" cause fail of Import to Checkbot

Workaround: When the following error appears during an import to Checkbot. 

inline image in article

Navigate to SCIA and perform a manual export of SAF file. 

inline image in article

If the export fails, click on "INFO" and the top lines inform you about the members that uses other LCS than "standard". 

inline image in article

Locate the members and change their LCS to "standard". Recalculate and launch the BIM link again.