Automatic anchoring code-selection with hooked anchors

The anchor type list includes hooked anchors for EN designs. Code-check of tension and shear resistance for anchorage according to Eurocode feature automatic differentiation between 1993-1-8 and 1992-4 code requirements based on anchor type.

The Anchor type – 'Hooked anchors' – can be selected from the drop-down menus:

For this anchor type, pull-out resistance is checked with an assessment according to EN 1992-1-1.

The steel resistance values for anchors are taken into account according to this simple rule:

    • Post-installed anchors (type = Straight) – resistance according to EN 1992-4 
    • Cast-in anchors (type = Washer plate or Hook) – resistance according to EN 1993-1-8

This improvement is also based on FprEN 1993-1-8:2023 and is aligned with recommendations of the Dutch ECCS TC10 group. For more information about the approach of distinguishing between Post-installed and Cast-in  anchors, see this document: Column bases in shear and normal force.

Download the latest version of IDEA StatiCa and try all the features

Related articles

Release notes IDEA StatiCa 24.0

EN anchoring code-check improvement

Import of anchoring from Connection to Detail

Connection Wednesdays – Focus on anchoring