Learning Module: Prying action

Questo articolo è disponibile in:

Connection design can be difficult to teach, given the detailed nature of the topic and the fundamentally three-dimensional behavior of most connections. However, connections are critically important, and lessons learned in the study of connection design, including load path and identification and evaluation of failure modes, are general and applicable to structural design broadly. IDEA StatiCa uses a rigorous nonlinear analysis model and has an easy-to-use interface with a three-dimensional display of results (e.g., deformed shape, stress, plastic strain) and thus is well suited for the exploration of the behavior of structural steel connections. Building on these strengths, a suite of guided exercises that use IDEA StatiCa as a virtual laboratory to help students learn about concepts in structural steel connection behavior and design was developed. These learning modules were primarily targeted to advanced undergraduate and graduate students but were made suitable for practicing engineers as well. The learning modules were developed by Associate Professor Mark D. Denavit from the University of Tennessee, Knoxville.


Learning Objective

After performing this exercise, the learner should be able to describe prying action, the parameters that affect it, and how it affects the design of structural steel connections.

Background

Bolts in tension can be subjected to greater force than expected due to a phenomenon known as prying action.

While not limited to T-stubs and angles, prying action is most clearly identified and evaluated with these components. Consider the all-bolted double-angle connection shown in the figure below. The beam, acting as a chord or collector, is subject to 60 kips of tension (for simplicity, shear in the beam is neglected). 5 bolts connect each angle to the column flange for a total of 10 bolts between the angles and the column flange. Based on a simple analysis, one may expect the tension in each bolt to be 60 kips/10 bolts = 6 kips per bolt. However, the actual tension force is greater, about 14 kips per bolt for the connection shown below, because the toes of the angles are bearing on the column flange and the bearing force adds to the bolt tension.

The magnitude of the bearing force depends on the stiffness and strength of the connected elements and bolts.

  • If the angles are very thin, they will yield both near the heel and near the bolt line, and the strength of the angles will control even when considering additional tension in the bolts due to prying action. The Eurocode describes this as failure mode 1.
  • If the angles are very thick, the leg will not bend enough to overcome the elongation of the bolt, and the toe will not contact the column flange. In this case, there is no prying action, the strength of the bolts will control, and a simple analysis is sufficient to estimate the force in the bolts. The Eurocode describes this as Mode 3.
  • For angle thicknesses between these extremes, the flexural strength of the angles and the tensile strength of the bolts can control simultaneously.

In Eurocode 3 (CEN, 2005), these different behaviors are called “Mode 1: Complete yielding of the flange”; “Mode 2: Bolt failure with yielding of the flange”; and “Mode 3: Bolt failure” and correspond to thin, intermediate, and thick connecting elements, respectively.

Equations to assess prying action are presented in AISC Manual Part 9 (AISC, 2023). These equations can be used to efficiently assess prying action, but they use abstracted parameters that obscure the physical behavior. This exercise is intended to help develop physical intuition on prying action. 

Connection

The connection examined in this exercise is inspired by the double-tee moment connection but consists only of the column and the tension T-stub (the beam and compression T-stub are not included).

File di esempio


The T-stub is made of two plates to allow easy variation of the geometry during the exercise. The plates are butt welded for simplicity. The column is relatively large and provided with a stiffener to form a firm base for the T-stub – prying action can also occur if the column flange bends and contacts the T-stub. The column is modeled in IDEA StatiCa as continuous and with a N-Vy-Mz model type so that the applied tension is resisted by shear at the top and bottom of the column and entry of the shear force is not necessary (i.e., unbalanced forces are okay).

Procedure

The procedure for this exercise assumes that the learner has a working knowledge of how to use IDEA StatiCa (e.g., how to navigate the software, define and edit operations, perform analyses, and look up results). Guidance for how to develop such knowledge is available on the IDEA StatiCa website (https://www.ideastatica.com/).

Retrieve the IDEA StatiCa file for the example connection provided with this exercise. Open the file in IDEA StatiCa. To perform the exercise, follow the narrative, complete the tasks, and answer the questions.

Fnt = 90 ksi (AISC Specification Table J3.2)

Ab = π/4 d2 = π/4 (0.75 in.)2 = 0.442 in.2

Rn = FntAb = (90 ksi)(0.442 in.2) = 39.8 kips

\(\phi\)Rn = 0.75(39.8 kips) = 29.8 kips

Alternatively, this value can be obtained directly from AISC Manual Table 7-2

\(\phi\)Rn = (8 bolts)(29.8 kips/bolt) = 238.4 kips

No. The maximum plastic strain is 287.0% (compared to the limit of 5%) and the bolt utilization is 235.5%.

The connection can support 111.1 kips of applied tension. Plastic strain in the flange plate controls the strength. The maximum bolt utilization is 80%.

All eight bolts have about 23.8 kips of tension.

The applied force in each bolt is (111.1 kips)/(8 bolts) = 13.9 kips, which is 58% of 23.8 kips.

The bearing force is 23.8 kips – 13.9 kips = 9.9 kips per bolt, or 79.2 kips total.

The stress occurs over an area of approximately 2 × (2 in.) × (12 in.) = 48 in.2, resulting in an estimated stress of 79.2 kips / 48 in.2 = 1.65 ksi.

The maximum bearing stress (i.e., stress in contacts) is 9.5 ksi. The average bearing stress past the bolt line appears to be less than 2 ksi, consistent with the estimated stress.

The flange plate is in double curvature. The greatest bending stresses are near the stem plate and at the bolt lines.

Yes, the connection can support 238.4 kips of applied load. The maximum plastic strain is 0.1% (compared to the limit of 5%) and the bolt utilization is 99.9%.

All eight bolts have about 29.8 kips of tension.

The applied force in each bolt is (238.4 kips)/(8 bolts) = 29.8 kips, which is 100% of the load in the bolts.

The bearing stress (i.e., stress in contacts) is zero.

The flange plate is in single curvature and the greatest bending stresses are near the stem plate.

Complete the table shown below by determining the maximum force that the connection can support for a variety flange plate thickness, then recording that force along with the maximum plastic strain and maximum bolt utilization at that force.

Flange Plate Thickness (in.)Maximum Force (kips)Maximum Plastic Strain (%)Maximum Bolt Utilization (%)
  1/4   
  5/1653.05.076.8
  3/870.84.977.7
  1/2   
  5/8158.15.091.3
  3/4185.24.999.9
  7/8   
1     223.25.097.9
1  1/4238.40.199.9
1  1/2   
Flange Plate Thickness (in.)Maximum Force (kips)Maximum Plastic Strain (%)Maximum Bolt Utilization (%)
  1/437.54.976.9
  5/1653.05.076.8
  3/870.84.977.7
  1/2111.15.080.0
  5/8158.15.091.3
  3/4185.24.999.9
  7/8203.35.099.3
1     223.25.097.9
1  1/4238.40.199.9
1  1/2238.40.199.9
  • Strength increases with increasing thickness rapidly at first, then slows, and eventually plateaus.
  • Plastic strain controls for the thinner plates, the bolts control for thicker plates, both control for the 3/4 in. to 1 in. thick plates.

11. Does the strength of the connection increase, decrease, or stay the same when the following dimensions are increased? Consider how the answer might be different for different flange plate thicknesses.

Increasing the width (without increasing the number of bolts) increases the strength of the flange plate. If the flange plate is thick and there is no prying action this will have no effect on the strength of the connection. If there is prying action, the connection strength will increase.

Increasing this distance will not matter for thin flange plates (Eurocode Mode 1) or thick flange plates (Eurocode Mode 3), but will decrease the bearing stress and increase connection strength for intermediate thickness flange plates (Eurocode Mode 2).

If the flange plate is thick and there is no prying action changing this dimension will have no effect on the strength of the connection (however, increasing this dimension will result in prying action occurring for larger plate thicknesses). If there is prying action, increasing this dimension will decrease the connection strength.

Increasing the diameter of the bolts increases their tensile strength. When the plate is thin, increasing bolt diameter will have some effect by removing more material for the bolt holes (a strength reduction) and by shifting the location of the yield line near the bolts (a strength increase). For thicker flange plates the increased bolt strength will increase connection strength.

  • Different underlying model. The AISC equations are based on a simplified model of behavior. IDEA StatiCa uses a detailed CBFEM model.
  • The AISC equations use Fu, IDEA StatiCa uses Fy

References

AISC. (2022). Seismic Provisions for Structural Steel Buildings. American Institute of Steel Construction, Chicago, Illinois.

CEN. (2005). Eurocode 3: Design of steel structures - Part 1-8: Design of joints. European Committee for Standardization, Brussels, Belgium.